How much reserve do you need?
Add up three days of essential appliance energy, allow for conversion losses and system overheads, then retain a separate emergency reserve. Compare that total with the battery energy actually available at the start. Test a scenario with no useful solar contribution, and decide in advance when to reduce demand or use a safe alternative.
Three grey days can expose the gap between a system that works through a normal night and one that supports you through an extended shortfall. A battery percentage alone cannot tell you whether the fridge, lighting and water supply will last until the weather improves.
This guide builds an illustrative 72-hour plan. Replace every example figure with your measurements and equipment limits. It is a planning worksheet, not a specification for buying or installing a battery.
1. Define what must keep working
Write three lists: essential, deferrable and switched off during the shortfall. A fridge, necessary communications, modest lighting and a water pump might be essential in one cabin. Another household may need different equipment or much more energy.
Include all equipment needed to provide a service. A boiler may need electrical controls and pumps; an internet connection may need more than a router. Powering your own equipment does not guarantee the external network will remain available.
Medical equipment requires an individual continuity plan agreed with the equipment supplier and care team. Do not rely on this general example or postpone a necessary move to a supported location while waiting for sunshine. Ready.gov’s power-outage guidance highlights planning for electrically powered medical devices.
Put discretionary electric heating, cooking, laundry and workshop use into the budget explicitly if they must remain available. A 2,000 W heater running for one hour uses 2 kWh: more than the entire daily appliance allowance in the example below. Plan meals and safe warmth before the shortage arrives.
2. Measure daily energy, not just running watts
For a steady load, multiply watts by operating hours to obtain watt-hours. Divide by 1,000 for kilowatt-hours. For cycling appliances, measure consumption over several representative days with a suitable energy meter. Record room conditions and normal use alongside the readings.
A refrigerator’s compressor does not run continuously, and its daily consumption can change. Our guide to calculating fridge runtime from measured daily use explains why a nameplate wattage alone is insufficient. Use a suitably rated meter; ask an electrician about monitoring fixed wiring.
| Appliance | Example daily use | Energy per day |
|---|---|---|
| Fridge | Measured daily total | 800 Wh |
| Router | 10 W × 12 hours | 120 Wh |
| Two LED lights | 10 W combined × 5 hours | 50 Wh |
| Phone charging | Measured charger-input total | 40 Wh |
| Small water pump | 60 W × 0.5 hours | 30 Wh |
| Total | At appliance inputs | 1,040 Wh / 1.04 kWh |
Here, all loads are supplied through AC outlets. Direct DC loads need their own conversion assumptions. Do not add phone-battery capacity on top of a measured charger-input figure: that would count the same use twice.
3. Translate appliance use into battery demand
The US Department of Energy explains that storage involves energy losses and distinguishes energy capacity from power capacity. For our calculation, assume 90% conversion efficiency for the appliance load, plus a separately measured 6 W inverter overhead throughout all 72 hours.
Worked 72-hour calculation
Appliance energy: 1.04 × 3 = 3.12 kWh.
Battery energy for those loads: 3.12 ÷ 0.90 = 3.47 kWh.
Separate inverter overhead: 6 × 72 ÷ 1,000 = 0.432 kWh.
Total battery demand: approximately 3.90 kWh, before retaining an emergency reserve.
These efficiency and overhead values are assumptions, not typical-performance promises. If a measured whole-system discharge test already includes inverter losses and idle use, do not add them again. Include any additional battery heating, controls or other equipment that your measurement excludes.
Use capacity available under the manufacturer’s permitted operating conditions. Nominal capacity, advertised usable capacity and energy delivered at an AC socket are different quantities. Temperature, ageing, settings and discharge limits can change what is available. Our winter garage battery checklist covers questions to ask about cold conditions.
Optional further reading: view the separate energy-information offer (affiliate link). We have not tested the product or verified its claims; it is not the basis of these calculations.
4. Keep the emergency reserve separate
Suppose a hypothetical battery has 5 kWh of usable DC energy when full, after its manufacturer’s protective buffer. You choose to retain another 1 kWh for unexpected needs. This leaves 4 kWh for the planned period.
The example’s 3.90 kWh demand just fits, leaving approximately 1.10 kWh. That is only 0.10 kWh above your chosen reserve. It is a tight arithmetic result, not a robust guarantee.
If appliance demand rises by 20%, three-day battery demand becomes approximately 4.59 kWh with the same efficiency and overhead. Retaining 1 kWh would then require about 5.59 kWh of usable DC energy at the start. This stress test is an editorial planning assumption, not a universal sizing rule.
Starting charge matters equally. Beginning with 4 kWh instead of 5 kWh leaves only 3 kWh above the reserve. At the original daily battery demand of approximately 1.30 kWh, that covers roughly 2.3 days. A larger battery that starts partly empty may offer less protection than expected.
5. Treat cloudy-day generation cautiously
Cloud cover does not necessarily mean zero generation. However, the Department of Energy notes that solar production varies with weather, season, time and obstructions. A fixed percentage of panel rating is a weak basis for a three-day promise.
Start with a zero-solar stress test. Then make a second scenario using conservative site records from comparable weather and season. Label whether the generation figure is measured at panels, the controller, the battery or the AC output, so losses are accounted for consistently.
Credit only energy that actually reduces battery demand or reaches storage. Check the sequence: a possible recharge on the third afternoon cannot run a fridge through an empty battery on the second night. Review morning and evening balances rather than relying solely on a 72-hour total.
6. Check whether essential appliances can start
Kilowatt-hours describe endurance; watts describe demand at a particular moment. Check the inverter’s continuous rating, its permitted starting surge and surge duration, and the battery’s discharge limits against simultaneous loads.
A fridge or pump may need a brief starting demand above its normal running power. A large energy store does not solve an inadequate inverter. The Australian Government’s battery guidance also explains why energy capacity and output power both matter.
Confirm approved connections, protection and operating modes with the equipment manufacturer or installer. For fixed circuits, use a qualified electrician. Our shed inverter guide provides related questions. Check that any economy mode reliably wakes for your essential loads before depending on it.
7. Set checkpoints before the weather arrives
Keep a short paper log as well as any app. At the same morning and evening times, record available energy, consumption since the previous check, actual solar input and the next expected opportunity to recharge.
| Checkpoint | Expected energy remaining | Energy needed including 1 kWh reserve |
|---|---|---|
| Start | 5.00 kWh | 4.90 kWh for 72 hours |
| After 24 hours | 3.70 kWh | 3.60 kWh for 48 hours |
| After 48 hours | 2.40 kWh | 2.30 kWh for 24 hours |
| After 72 hours | 1.10 kWh | 1.00 kWh retained reserve |
If remaining energy falls below the next-period requirement plus reserve, act immediately: remove deferrable loads, revise the budget and start the agreed fallback. Set an earlier trigger if arranging that fallback takes time. Do not wait for automatic low-battery shutdown.
Saving energy must not compromise essential services. Do not routinely disconnect refrigeration merely to meet a spreadsheet target. Monitor its temperature and maintain a food-safety contingency. Review the priorities with everyone using the system.
8. Plan the fallback and the recovery
Your fallback might be a compatible pre-charged spare, an accessible approved charging location, a professionally arranged backup supply or moving essential activities elsewhere. Verify the practical details in advance: transport, connectors, charging limits and the time needed.
If using a fuel generator, follow its manual and local requirements. CDC guidance says to operate it outdoors at least 20 feet (about 6 metres) from doors, windows and vents; never in a garage or enclosed space. Keep exhaust away from buildings and use working carbon-monoxide alarms. Have any connection to fixed wiring professionally arranged; never backfeed a socket.
After the clouds clear, solar must support current loads as well as refill the battery. For example, replacing 3 kWh with only 1 kWh of daily surplus reaching storage takes roughly three days. Keep discretionary consumption restrained until the reserve is restored.
If you are comparing broader energy ideas, the optional energy-information promotion (affiliate link) is separate from this reserve plan. It does not establish equipment suitability or guaranteed savings.
Frequently asked questions
Will a 5 kWh battery last three cloudy days?
It depends on usable starting energy, load, losses, temperature and your retained reserve. Our hypothetical 5 kWh usable-DC example only narrowly covers its stated loads when starting full.
Should I buy more panels or more battery storage?
First identify the shortfall. More storage needs an opportunity to charge; more panels may improve replenishment but cannot guarantee output during poor weather. Ask an installer to compare seasonal generation, demand and recharge time.
Can I test the plan beforehand?
Yes: log normal essential-load operation under safe conditions, with a fallback available and a stopping threshold above the protected limit. Do not intentionally run critical equipment to failure. Compare actual battery use with the worksheet and adjust.
What should I write on the final reserve sheet?
List essential loads, measured daily energy, usable starting charge, loss assumptions, reserve, checkpoint thresholds, who will act and the fallback contact or location. Date it and update it when appliances or battery settings change.
Make the reserve plan specific to your home
Start with measurements and a realistic fallback. For optional further reading, the link below opens a separate, untested energy-information product; it is not equipment or an installation service.
View the energy-information offer — affiliate linkSources and further reading
- US Department of Energy: Solar Energy and Storage Basics — variable production, losses, energy and power.
- Australian Government: Batteries — capacity and power considerations.
- Ready.gov: Power Outages — preparedness and medical-device planning.
- CDC: Use a Generator Safely — outdoor siting and carbon-monoxide precautions.
Sources checked 4 October 2026. Numerical examples are original illustrative calculations, not product tests.